Below is the attic ventilation section.
Attic ventilation requirements irc.
2018 is a cycle year.
Also when using a vapor retarder in an attic space irc 2012 limits the net free ventilation reduction from 1 150 to 1 300 for buildings in climate zones 6 7 and 8.
Required ventilation openings shall open directly to the outside air.
The international codes i codes are the widely accepted comprehensive set of model codes used in the us and abroad to help ensure the engineering of safe sustainable affordable and resilient structures.
The following are the requirements taken directly from the irc.
Proper attic ventilation consists of a balance between air intake at your eaves soffits or fascias and air exhaust at or near your roof ridge.
Attic ventilation shall not be required when determined not necessary by the code official due to atmospheric or climatic conditions.
The majority of the requirements related to attic ventilation have not changed much from the previous editions.
Federal housing authority recommends a minimum of at least 1 square foot of attic ventilation evenly split between intake and exhaust for every 300 square feet of attic floor space.
Ventilation openings shall have a least dimension of 1 16 inch 1 6 mm minimum and 1 4 inch 6 4 mm maximum.
2015 international residential code for attic ventilation air vent inc.
Openings in roof framing members shall conform to the requirements of section r802 7.
R806 2 minimum vent area.
Enclosed attics and enclosed rafter spaces formed where ceilings are applied directly to the underside of roof rafters shall have cross ventilation for each separate space by ventilating openings protected against the entrance of rain or snow.
Let owens corning roofing help you calculate exactly how much ventilation you will need for a healthy and balanced attic with our 4 step ventilation calculator.
Unless local and state rules override them the rules listed in the irc are the basis for all code requirements for residential housing.
The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process.
Irc section r408 1 ventilation the irc prescriptions for venting crawl spaces are contained in section r408 in several paragraphs.
Air vent provides a complete line of ventilation products that meet the highest standards for quality and performance.
The ventilation amount and opening size requirements can be found in section 806 roof ventilation of chapter 8 roof ceiling construction.